【发布时间】:2020-03-01 13:21:09
【问题描述】:
我正在尝试通过 SPI 设置 esp32(主)和 stm32(从)之间的通信。 esp32在micropython下运行,发送四个字节,例如
spi.write_readinto(b'\x31\x32\x33\x34', buf)
stm32' 代码在这里(而不是这个我使用SPI_InitDef.SPI_NSS = SPI_NSS_Soft;)
void SPI_Init(void) {
...
// initialize SPI slave
// for slave, no need to define SPI_BaudRatePrescaler
SPI_InitDef.SPI_Direction = SPI_Direction_2Lines_FullDuplex;
SPI_InitDef.SPI_Mode = SPI_Mode_Slave;
SPI_InitDef.SPI_DataSize = SPI_DataSize_8b; // 8-bit transactions
SPI_InitDef.SPI_FirstBit = SPI_FirstBit_MSB; // MSB first
SPI_InitDef.SPI_CPOL = SPI_CPOL_Low; // CPOL = 0, clock idle low
SPI_InitDef.SPI_CPHA = SPI_CPHA_2Edge; // CPHA = 1
SPI_InitDef.SPI_NSS = SPI_NSS_Hard; // use hardware SS
SPI_InitDef.SPI_BaudRatePrescaler = SPI_BaudRatePrescaler_64; // APB2 72/64 = 1.125 MHz
SPI_InitDef.SPI_CRCPolynomial = 7;
SPI_Init(SPI1, &SPI_InitDef);
SPI_Cmd(SPI1, ENABLE);
NVIC_EnableIRQ(SPI1_IRQn);
//Тут мы разрешаем прерывание по приему
SPI_I2S_ITConfig(SPI1, SPI_I2S_IT_RXNE, ENABLE);
}
void main() {
/* Setup SysTick Timer for 10ms interrupts */
if (SysTick_Config(SystemCoreClock / 100))
{
/* Capture error */
while (1);
}
/* Configure the SysTick handler priority */
NVIC_SetPriority(SysTick_IRQn, 0x0);
SPI_Init();
while(1) {
while(!SPI_I2S_GetFlagStatus(SPI1, SPI_I2S_FLAG_RXNE));
for (u8 i=0; i<4; i++) {
printf("0x%02x ", SPI_I2S_ReceiveData(SPI1));
}
printf("\r\n");
}
}
但是当我发送四个字节 0x31 0x32 0x33 0x34(分析器确认字节已发送)并且我的 stm 只得到 0x31 0x32 0x31 0x32
UPD 我使用 std periph 库,SPI_I2S_ReceiveData 是从 SPI 读取字节的本机方法。
uint16_t SPI_I2S_ReceiveData ( SPI_TypeDef * SPIx )
Returns the most recent received data by the SPIx/I2Sx peripheral.
Parameters:
SPIx,: To select the SPIx/I2Sx peripheral, where x can be: 1, 2 or 3 in SPI mode or 2 or 3 in I2S mode or I2Sxext for I2S full duplex mode.
Return values:
The value of the received data.
uint16_t SPI_I2S_ReceiveData ( SPI_TypeDef * SPIx )
Returns the most recent received data by the SPIx/I2Sx peripheral.
Parameters:
SPIx,: To select the SPIx/I2Sx peripheral, where x can be: 1, 2 or 3 in SPI mode or 2 or 3 in I2S mode or I2Sxext for I2S full duplex mode.
Return values:
The value of the received data.
但也许我在读取所有数据之前退出了 IRQ。我发现运行while循环直到最后一个字节的传输完成
【问题讨论】:
-
旁注 - 您应该避免从事务中打印调试输出。调试信息通道可能会停止您的 SPI 事务,从而丢失数据。
-
可能有原因导致它意外工作。谢谢,我试试
-
请在此站点上包含代码。
-
关于您的编辑:我不明白您为什么要谈论中断。您的代码正在轮询而不是中断(或者我可能错过了什么)。
-
"我发现一直运行while循环,直到最后一个字节的传输完成"是什么意思?知道接收是否完成的唯一方法是使用我描述的设置轮询标志 EOT。 RXNE 不会告诉您接收完成,只有一个字节(或字)可用。