【发布时间】:2012-08-02 17:52:25
【问题描述】:
我正在尝试向 BizTalk 发送 HL7 消息,并收到错误代码 0xC0C01B4e(路由失败报告)和消息:
的路由失败报告
我已经在最后一天工作了,现在收到这条消息,完全难以置信。
我的场景:
1 Request/Response Recieve Port named HL7Test.In
1 Receive Location for the Receive Port called HL7Test.In.MLLP
Type is MLLP
Receive pipeline is BTAHL72XRecievePipeline
Send pipeline is BTAHL72XSendPipeline
1 Send Port
Type is file
Send pipeline is Passthrough
Filter is BTS.ReceivePortName == HL7Test.In
1 Party configuration called "REG", with the following BTAHL7 configuration:
Acknowledgemnt type: OriginalMode
Validate body segments: Enabled
Validate custom datat types: Enabled
Alow trailing delimiters: Enabled
Schema namespace: http://microsoft.com/HealthCare/HL7/2X
I've deployed the BTAHL7V2XCommon, BTAHL7V21Common and ADT message schemas
我使用 MLLP 从第 3 方应用程序发送 HL7 消息 没有返回 ack 文件未写入 如上所述,生成 1 个不可恢复错误。
我要发送的信息是:
MSH|^~\&|REG|FAC|||201207271419||ADT^A04|504111|D|2.1|||AL|AL|
EVN|A04|201207271419||02 PID|1||M11||REGRIHSOT^xyz^2^3^5^6
NK1|1|雷格里索^妻子^3^4^5^6|W|1^2^城市^BC^V1S 0A7^6^7^8|
PV1|1|E|KAMRIHED|||||MITD4||||||HO||||ED||BC|||||||||||||||||FAC||注册|||201207271417|
ZAD|邮件^1^^城市^BC^V1S 0A7|PHYS^1^^坎卢普斯^BC^V1S 0A7| ZTZ|PT|
ZGC|^^|
一小时前一切正常。
【问题讨论】:
标签: biztalk biztalk-2010 btahl7