【发布时间】:2021-08-28 20:39:23
【问题描述】:
微软奥尔良 v3.4.3 领事集群 在 K8S 中运行
siloBuilder
.UseConsulClustering(opt =>
{
opt.Address = new Uri(AppConfig.Orleans.ConsulUrl);
opt.AclClientToken = AppConfig.Orleans.AclClientToken;
})
.Configure<ClusterOptions>(options =>
{
options.ClusterId = AppConfig.Orleans.ClusterID;
options.ServiceId = AppConfig.Orleans.ServiceID;
})
.siloBuilder.UseKubernetesHosting();
我根据doc为我的POD配置了标签和环境变量。
- name: ORLEANS_SERVICE_ID #Required by Orleans
valueFrom:
fieldRef:
fieldPath: metadata.labels['orleans/serviceId']
- name: ORLEANS_CLUSTER_ID #Required by Orleans
valueFrom:
fieldRef:
fieldPath: metadata.labels['orleans/clusterId']
- name: POD_NAME
valueFrom:
fieldRef:
fieldPath: metadata.labels['statefulset.kubernetes.io/pod-name']
- name: POD_NAMESPACE
valueFrom:
fieldRef:
fieldPath: metadata.namespace
- name: POD_IP
valueFrom:
fieldRef:
fieldPath: status.podIP
它是一个 StatefulSet,只有 1 个 POD 用于测试。 在初次启动时,它运行良好。 但是,每次我重新启动 POD 时,都会在 Consul 中创建一个新条目。
并且它在随后的启动中崩溃。
日志说
System.AggregateException: One or more errors occurred. (Failed to get ping responses from 1 of 1 active silos. Newly joining silos validate connectivity with all active silos that have recently updated their 'I Am Alive' value before joining the cluster. Successfully contacted: []. Failed to get response from: [S10.18.123.218:11111:361110184])
---> Orleans.Runtime.MembershipService.OrleansClusterConnectivityCheckFailedException: Failed to get ping responses from 1 of 1 active silos. Newly joining silos validate connectivity with all active silos that have recently updated their 'I Am Alive' value before joining the cluster. Successfully contacted: []. Failed to get response from: [S10.18.123.218:11111:361110184]
at Orleans.Runtime.MembershipService.MembershipAgent.ValidateInitialConnectivity()
at Orleans.Runtime.MembershipService.MembershipAgent.BecomeActive()
at Orleans.Runtime.MembershipService.MembershipAgent.<>c__DisplayClass26_0.<<Orleans-ILifecycleParticipant<Orleans-Runtime-ISiloLifecycle>-Participate>g__OnBecomeActiveStart|6>d.MoveNext()
--- End of stack trace from previous location where exception was thrown ---
at Orleans.Runtime.SiloLifecycleSubject.MonitoredObserver.OnStart(CancellationToken ct)
at Orleans.LifecycleSubject.OnStart(CancellationToken ct)
at Orleans.Runtime.Scheduler.AsyncClosureWorkItem.Execute()
at Orleans.Runtime.Silo.StartAsync(CancellationToken cancellationToken)
at Orleans.Hosting.SiloHost.StartAsync(CancellationToken cancellationToken)
at Orleans.Hosting.SiloHostedService.StartAsync(CancellationToken cancellationToken)
at Microsoft.Extensions.Hosting.Internal.Host.StartAsync(CancellationToken cancellationToken)
at Microsoft.Extensions.Hosting.HostingAbstractionsHostExtensions.RunAsync(IHost host, CancellationToken token)
at Microsoft.Extensions.Hosting.HostingAbstractionsHostExtensions.RunAsync(IHost host, CancellationToken token)
at UBS.OrleansServer.EntryPoint.Start() in /app/UBS/OrleansServer/EntryPoint.cs:line 102
--- End of inner exception stack trace ---
我必须删除 Consul 中的所有条目,然后重新启动 POD,然后一切正常。
POD_NAME对于StatefulSet的POD来说是一样的,每次POD重启都会在Consul中创建一个新条目是否正确?
可能是什么原因?
提前致谢
更新 经过几轮崩溃并重新启动,终于不再崩溃了。在日志中我看到以下消息
ProcessTableUpdate (called from DeclareDead) membership table: 5 silos, 1 are Active, 4 are Dead, Version=<31, 28123>. All silos: [SiloAddress=S10.18.123.244:11111:361163684 SiloName=ubs-job-dev-0 Status=Active, SiloAddress=S10.18.123.200:11111:361158057 SiloName=ubs-job-dev-0 Status=Dead, SiloAddress=S10.18.123.210:11111:361161905 SiloName=ubs-job-dev-0 Status=Dead, SiloAddress=S10.18.123.217:11111:361157424 SiloName=ubs-job-dev-0 Status=Dead, SiloAddress=S10.18.123.244:11111:361163558 SiloName=ubs-job-dev-0 Status=Dead]
SiloName 永远不会改变,StatefulSet 中只有一个 POD,但它看到 5 个 silo,其中 4 个已经死亡。似乎每个新的 POD,即使 pod 名称没有改变,也被视为一个新的筒仓。这是预期的吗?
【问题讨论】: