分两部分解决,还有一个未解决的问题。
从 GitHub 上的 WDK 驱动程序示例开始,https://github.com/Microsoft/Windows-driver-samples
在 SerialReadSymName() 函数上,我将其更改为返回我想要的符号名称,而不是让它使用 ComDB 提供的索引。请注意,我必须从 inf 文件中的 UpperFilters 键中删除 serenum 才能使用它。
-
现在我有了可以使用的工作设备名称(即 COM1、COM2 等),但在这个阶段我还是将串行端口“友好名称”重命名了。为了解决这个问题,我用以下代码更新了SerialCreateOpen():
if (!extension->FriendlyNameSet) //Added this guard to the device extension
{
DWORD f_set = 1;
HANDLE keyHandle;
MySerialSetFriendlyName(extension);
extension->FriendlyNameSet = TRUE;
}
函数MySerialSetFriendlyName()定义如下:
NTSTATUS MySerialSetFriendlyName(PSERIAL_DEVICE_EXTENSION pDevExt)
{
NTSTATUS status = STATUS_SUCCESS;
WCHAR *FriendlyName, *fnprefix, *fnsuffix, *instanceId;
ULONG FriendlyNameLength, instanceLength, temp, i;
fnprefix = BASE_FRIENDLY_NAME_PREFIX_STR;
fnsuffix = BASE_FRIENDLY_NAME_SUFFIX_STR;
temp = pDevExt->InstanceIdentifier;
instanceLength = 0;
while (temp)
{
instanceLength++;
if (temp < 10)
temp = 0;
else
{
temp /= 10;
if (!temp)
instanceLength++;
}
}
if (instanceLength)
{
instanceId = ExAllocatePool(NonPagedPool, instanceLength);
temp = pDevExt->InstanceIdentifier;
WCHAR digit = L'X';
for (i = 0; i < instanceLength; i++)
{
switch (temp % 10)
{
case 0: digit = L'0'; break;
case 1: digit = L'1'; break;
case 2: digit = L'2'; break;
case 3: digit = L'3'; break;
case 4: digit = L'4'; break;
case 5: digit = L'5'; break;
case 6: digit = L'6'; break;
case 7: digit = L'7'; break;
case 8: digit = L'8'; break;
case 9: digit = L'9'; break;
default: digit = L'X'; break;
}
instanceId[instanceLength - i - 1] = digit;
temp /= 10;
}
FriendlyNameLength = BASE_FRIENDLY_NAME_PREFIX_LEN + instanceLength + BASE_FRIENDLY_NAME_SUFFIX_LEN + 1;
FriendlyName = ExAllocatePool(NonPagedPool, FriendlyNameLength * sizeof(WCHAR));
RtlZeroMemory(FriendlyName, FriendlyNameLength * sizeof(WCHAR));
for (i = 0; i < BASE_FRIENDLY_NAME_PREFIX_LEN; i++)
{
FriendlyName[i] = fnprefix[i];
}
for (i = 0; i < instanceLength; i++)
{
FriendlyName[i + BASE_FRIENDLY_NAME_PREFIX_LEN] = instanceId[i];
}
for (i = 0; i < BASE_FRIENDLY_NAME_SUFFIX_LEN; i++)
{
FriendlyName[i + BASE_FRIENDLY_NAME_PREFIX_LEN + instanceLength] = fnsuffix[i];
}
if (pDevExt->PnpRegistryKey)
status = RtlWriteRegistryValue(RTL_REGISTRY_ABSOLUTE, (PCWSTR)pDevExt->PnpRegistryKey, (PCWSTR)L"FriendlyName", REG_SZ, FriendlyName, FriendlyNameLength * sizeof(WCHAR));
else
status = STATUS_INSUFFICIENT_RESOURCES;
KdPrintEx((DPFLTR_DEFAULT_ID, DPFLTR_ERROR_LEVEL, "%s :: Changed friendly name to %S (NTSTATUS %08X)\n", __FUNCTION__, FriendlyName, status));
if (!NT_SUCCESS(status))
{
status = STATUS_SUCCESS; //it is enough that we came through here
}
}
return status;
}
(BASE_FRIENDLY_NAME_... 是存储我选择的友好名称前缀(比如L"Communications Port (COM")和后缀(比如L")")的宏。您可以根据需要制作它们,但您确实需要将它们的长度单独存储宏,然后)
这样,友好名称将在第一个设备打开时设置。为了确保这意味着设备会立即获得正确的名称,我刚刚编写了一个设备协同安装程序,它在DIF_INSTALLDEVICE 命令上进行后处理,快速打开和关闭端口。这本身就值得一篇文章,而且很简单,所以我现在不会发布。
唯一未解决的问题是:
- 这样,ComDB 仍然会记住错误的编号顺序。您可以通过更改 Windows 注册表中的 Com Name Arbiter 位掩码来强制它按您的意愿运行,如我在问题中提供的链接中指定的那样,但您不能对仍然绑定到某些 I/ 的 COM1 和 COM2 执行此操作O 范围和 IRQ。
所以,只要您永远不需要在应用程序中访问 ComDB,它就可以工作!