Abstract
若在Quartus II 7.2下啟動ModelSim-Altera 6.1g進行模擬,可能會遇到以下錯誤訊息而無法模擬成功。

Introduction
使用環境:Quartus II 7.2 SP3 + ModelSim-Altera 6.1g

Error: Can't launch the ModelSim-Altera software -- the path to the location of the executables for the ModelSim-Altera software were not specified or the executables were not found at specified path.

Error: You can specify the path inthe EDA Tool Options page of the Options dialog box or using the Tcl command set_user_option.

Error: NativeLink simulation flow was NOT successful


Solution
Step 1:
設定NativeLink路徑

Tools -> Options -> General -> EDA Tool Options:
將ModelSim-Altera的路徑設定到c:\altera\72\modelsim_ae\win32aloem